Radiator HCS

null
Product Description Radiator HCS
Product Type 27-2063-3704/B300
Brand Bartec
  • Various compact types of construction, therefore favourable mounting dimensions
  • High heating capacity
  • Integrated antifreezing protection device in the connection cable
  • Large, black anodized convector surface
  • Ready for connection, maintenance-free

Description

BARTEC compact radiators are used as antifreezing and anticondensate heaters in potentially explosive areas. Their use guarantees maximum operating safety, since temperature fluctuations are effectively prevented or the required minimum temperatures are maintained. They reliably ensure that no malfunctioning through leakage current in electrical components, or other disturbances through corrosion formation on mechanical installation parts, can occur. Places of use include switch and control cabinets, transmitter protective boxes, measuring equipment, analytical cabinets for sample preparation etc.

Function

The thermostat located in the connection cable keeps the inside temperature in the required range and reliably prevents overshooting the permissible ambient temperature of the heater. In order to prevent accumulation of heat the specified fitting distances must be observed. Do not cover the fins, in order that free convection is not hindered. For applications involving higher holding temperatures, please contact us.

Construction

The radiators are fitted with a constant ohmic resistance. Through the special construction of the aluminium profile a chimney effect is produced which gives a uniform temperature distribution in the interior of enclosures and cabinets. In case of overheating, the heaters are permanently isolated from the mains supply, since the heat source is coupled with a temperature safety fuse.

Technical Data

Protection class IP 65, NEMA 4
Dimensions 52 mm x 50 mm x 155 mm (length x width x height)
Material black anodized aluminium, resistant to sea water
Installation Mounting position: Vertical flow through fins
Voltage AC 230 V
Power 40 W
Connection Hose line, EWKF 3 x 1.5 mm²; Ø 8.1 mm; length 3 m
Ambient temperature -50 °C up to +60 °C
Application temperature range: -50 °C up to +80 °C

Explosion Protection

Marking Ex II 2G Ex db IIC T4
Ex II 2D Ex tb IIIC T135 °C
Certification PTB 03 ATEX 1139 X
TC RU C-DE.GB06.B.00327
NEPSI GYJ13.1131
Datasheet
Declaration of Conformity
Operating Instructions
General Info

Description

BARTEC compact radiators are used as antifreezing and anticondensate heaters in potentially explosive areas. Their use guarantees maximum operating safety, since temperature fluctuations are effectively prevented or the required minimum temperatures are maintained. They reliably ensure that no malfunctioning through leakage current in electrical components, or other disturbances through corrosion formation on mechanical installation parts, can occur. Places of use include switch and control cabinets, transmitter protective boxes, measuring equipment, analytical cabinets for sample preparation etc.

Function

The thermostat located in the connection cable keeps the inside temperature in the required range and reliably prevents overshooting the permissible ambient temperature of the heater. In order to prevent accumulation of heat the specified fitting distances must be observed. Do not cover the fins, in order that free convection is not hindered. For applications involving higher holding temperatures, please contact us.

Construction

The radiators are fitted with a constant ohmic resistance. Through the special construction of the aluminium profile a chimney effect is produced which gives a uniform temperature distribution in the interior of enclosures and cabinets. In case of overheating, the heaters are permanently isolated from the mains supply, since the heat source is coupled with a temperature safety fuse.

Technical Data

Technical Data

Protection class IP 65, NEMA 4
Dimensions 52 mm x 50 mm x 155 mm (length x width x height)
Material black anodized aluminium, resistant to sea water
Installation Mounting position: Vertical flow through fins
Voltage AC 230 V
Power 40 W
Connection Hose line, EWKF 3 x 1.5 mm²; Ø 8.1 mm; length 3 m
Ambient temperature -50 °C up to +60 °C
Application temperature range: -50 °C up to +80 °C
Explosion Protection

Explosion Protection

Marking Ex II 2G Ex db IIC T4
Ex II 2D Ex tb IIIC T135 °C
Certification PTB 03 ATEX 1139 X
TC RU C-DE.GB06.B.00327
NEPSI GYJ13.1131
Download
Datasheet
Declaration of Conformity
Operating Instructions