KRM Capillary Tube Thermostat, 16 A
Product Description | KRM Capillary Tube Thermostat, 16 A |
Product Type | 27-6A..-61….. |
Brand | Bartec |
- 16 A switching capacity
- Capillary tube length of 1600 mm giving installation flexibility
- Compact enclosure
- Double units are standard
Description
The weather-proof capillary tube thermostat, KRM, is a mechanical change-over controller housed in a polyester enclosure. Heaters, fans, motors and other equipment are energised and de-energised when temperatures fall below or rise above certain limits. It can also be used to control the temperature in air, liquids and on various surfaces.
Function
Any change in temperature at the sensor bulb causes a change in the volume of fluid in the measuring system, which in turn results in a movement of the diaphragm membrane. This membrane is connected to a mechanical device that activates a microswitch. If the temperature at the sensor bulb exceeds the pre-set value, terminals 1 and 2 are opened. If the temperature falls below the minimum setting, the contacts automatically close.
Technical Data
Protection Class | IP 65 (EN 60529) |
Dimensions | see data sheet |
Temperature range | 0 °C to +300 °C (mechanical) |
Voltage | AC 400 V/50 Hz |
Current | 16 A (swiched current) |
Connection | 4 Terminals 2.5 mm² + 2 PE |
Ambient temperature | Application temperature range: -20 °C up to +65 °C |
- General Info
-
Description
The weather-proof capillary tube thermostat, KRM, is a mechanical change-over controller housed in a polyester enclosure. Heaters, fans, motors and other equipment are energised and de-energised when temperatures fall below or rise above certain limits. It can also be used to control the temperature in air, liquids and on various surfaces.
Function
Any change in temperature at the sensor bulb causes a change in the volume of fluid in the measuring system, which in turn results in a movement of the diaphragm membrane. This membrane is connected to a mechanical device that activates a microswitch. If the temperature at the sensor bulb exceeds the pre-set value, terminals 1 and 2 are opened. If the temperature falls below the minimum setting, the contacts automatically close.
- Technical Data
-
Technical Data
Protection Class IP 65 (EN 60529) Dimensions see data sheet Temperature range 0 °C to +300 °C (mechanical) Voltage AC 400 V/50 Hz Current 16 A (swiched current) Connection 4 Terminals 2.5 mm² + 2 PE Ambient temperature Application temperature range: -20 °C up to +65 °C - Download