Local control stations for Zone 2 and Zone 22

null
Product Description Local control stations for Zone 2 and Zone 22
Product Type A7-3…-…./….
Brand Bartec
  • The right size/material enclosure
  • Optimum functionality thanks to the great variety of components
  • Customised planning and implementation
  • Certified to many standards

Description

BARTEC produces local control stations for use in areas with flammable gases and dusts. Depending on the application area, the control stations are designed with the type of protection “Increased safety” or “Protection by enclosure”.
The explosion-protected local control stations are available in aluminium, polyester or stainless steel. When selecting the version, you can choose between a cabinet with door and an enclosure with screw cover. Control, signalling and display devices and remote I/O systems are installed according to customer specifications. The installation of industrial standard equipment in controls for Zone 22, type of protection t “Protection by enclosure” is possible.
The control elements can also be mounted on a mounting rail or in the front wall. Free installation areas can be designated for the subsequent installation of BARTEC control and signalling devices, which are then sealed using blanking plugs. All explosion-protected local control stations are supplied prewired on terminals.

Fields of application

Chemical and petrochemical industry, process and plant engineering, pharmaceutical and food industry, OFF SHORE areas.

Technical Data

Protection Class EN 60529/IEC 60529: IP max. IP 66
(higher degree of protection on request)
Material see data sheet
Voltage up to 1000 V
Current max. 160 A depending on devices fitted
Ambient temperature (special design on request)
-20 °C to +40 °C
-55 °C to max. +80 °C
(depending on fixtures)

Explosion Protection

Marking Ex II 3 G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic] IIA, IIB, IIC T6, T5, T4 Gc
Ex II 3(2) G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic Gb] IIA, IIB, IIC T6, T5, T4 Gc
Ex II 3(1) G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic Ga] IIA, IIB, IIC T6, T5, T4 Gc
Zone 22:
Ex II 3D Ex tc [ic] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Ex II 3(2)D Ex tc [ib Db] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Ex II 3(1)D Ex tc [ia Da] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Certification IBExU14ATEXB002
IECEx IBE 14.0028
CSA 70010169
CSA 70010169 Supplement
TC RU C-DE.BH02.B.00177
Datasheet
Operation instructions
Declaration of Conformity
Customer requirements – Local control station
General Info

Description

BARTEC produces local control stations for use in areas with flammable gases and dusts. Depending on the application area, the control stations are designed with the type of protection “Increased safety” or “Protection by enclosure”.
The explosion-protected local control stations are available in aluminium, polyester or stainless steel. When selecting the version, you can choose between a cabinet with door and an enclosure with screw cover. Control, signalling and display devices and remote I/O systems are installed according to customer specifications. The installation of industrial standard equipment in controls for Zone 22, type of protection t “Protection by enclosure” is possible.
The control elements can also be mounted on a mounting rail or in the front wall. Free installation areas can be designated for the subsequent installation of BARTEC control and signalling devices, which are then sealed using blanking plugs. All explosion-protected local control stations are supplied prewired on terminals.

Fields of application

Chemical and petrochemical industry, process and plant engineering, pharmaceutical and food industry, OFF SHORE areas.

Technical Data

Technical Data

Protection Class EN 60529/IEC 60529: IP max. IP 66
(higher degree of protection on request)
Material see data sheet
Voltage up to 1000 V
Current max. 160 A depending on devices fitted
Ambient temperature (special design on request)
-20 °C to +40 °C
-55 °C to max. +80 °C
(depending on fixtures)
Explosion Protection

Explosion Protection

Marking Ex II 3 G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic] IIA, IIB, IIC T6, T5, T4 Gc
Ex II 3(2) G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic Gb] IIA, IIB, IIC T6, T5, T4 Gc
Ex II 3(1) G Ex d e nA nC ma/mb/mc op is op sh q
ia/ib/ic [ic Ga] IIA, IIB, IIC T6, T5, T4 Gc
Zone 22:
Ex II 3D Ex tc [ic] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Ex II 3(2)D Ex tc [ib Db] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Ex II 3(1)D Ex tc [ia Da] IIIA, IIIB, IIIC
T80 °C, T100 °C Dc
Certification IBExU14ATEXB002
IECEx IBE 14.0028
CSA 70010169
CSA 70010169 Supplement
TC RU C-DE.BH02.B.00177
Download
Datasheet
Operation instructions
Declaration of Conformity
Customer requirements – Local control station