Power Distribution Boards for Zone 1/21 Applications

null
Product Description Power Distribution Boards for Zone 1/21 Applications
Product Type
Brand Bartec
  • Economic by reducing down times by fast access through windows
  • Reliable because of the harsh design in stainless steel enclosure
  • Compact through the combination of control and power distribution functions
  • Flexible concerning size and the used components
  • Completion of the BARTEC portfolio

Description

BARTEC offers a complete solution for distribution of power for light and heat tracing projects. Based on customer requirements, the safety technology provider supplies a combination of standardized and customized enclosure sizes containing the BARTEC breakers for circuit protection/power distribution as well as the control station for controlling and monitoring the customer system.
The components can be mounted on a galvanized metal or stainless steel frame with an option for sun and rain protection by a roof.
Application:Power feed-in/distribution for lighting, heating, motors, connectors
Area of usage: Zone 1, 2, 21, 22
Versions: ETO, up to 160 A, MCB, RCCB, RCBO

Technical Data

Dimensions Type 1: 380 mm x 300 mm, one flap
Type 2: 760 mm x 300 mm, two flaps
Type 3: 760 mm x 600 mm, three/four flaps
Connection MCB (Main circuit breaker):
1 pole up to 4 pole 0.5 A up to 40 A (15 values)
optional with one signal or auxiliary contact available
RCCB (Residual current circuit breaker):
1+N, 2 pole 25 A up to 63 A (3-values)/30, 100, 300, 500 mA residual current
RCBO (Residual current circuit breaker with overcurrent protection):
2 pole, 4 pole
6 A up to 40 A (8-values)/30, 300 mA residual current
optional with one signal or auxiliary contact available
Ambient temperature -20 °C to +40 °C (-55 °C to +55 °C)

Explosion Protection

Marking Zone 1:
Ex II 2G Ex de ia/ib m [ia/ib] IIC T5,4
Ex II 2D Ex td A21 IP 66/65 T 80°C, T 95°C
Certification ATEX, IECEx, CU TR
Datasheet
General Info

Description

BARTEC offers a complete solution for distribution of power for light and heat tracing projects. Based on customer requirements, the safety technology provider supplies a combination of standardized and customized enclosure sizes containing the BARTEC breakers for circuit protection/power distribution as well as the control station for controlling and monitoring the customer system.
The components can be mounted on a galvanized metal or stainless steel frame with an option for sun and rain protection by a roof.
Application:Power feed-in/distribution for lighting, heating, motors, connectors
Area of usage: Zone 1, 2, 21, 22
Versions: ETO, up to 160 A, MCB, RCCB, RCBO

Technical Data

Technical Data

Dimensions Type 1: 380 mm x 300 mm, one flap
Type 2: 760 mm x 300 mm, two flaps
Type 3: 760 mm x 600 mm, three/four flaps
Connection MCB (Main circuit breaker):
1 pole up to 4 pole 0.5 A up to 40 A (15 values)
optional with one signal or auxiliary contact available
RCCB (Residual current circuit breaker):
1+N, 2 pole 25 A up to 63 A (3-values)/30, 100, 300, 500 mA residual current
RCBO (Residual current circuit breaker with overcurrent protection):
2 pole, 4 pole
6 A up to 40 A (8-values)/30, 300 mA residual current
optional with one signal or auxiliary contact available
Ambient temperature -20 °C to +40 °C (-55 °C to +55 °C)
Explosion Protection

Explosion Protection

Marking Zone 1:
Ex II 2G Ex de ia/ib m [ia/ib] IIC T5,4
Ex II 2D Ex td A21 IP 66/65 T 80°C, T 95°C
Certification ATEX, IECEx, CU TR
Download
Datasheet