Description
This switching element can be universally used for switching, controlling and regulating operations within Ex-areas. The insert switch is audited by the PTB according to the latest EC guideline 94/9/EC. Devices equipped with these insert switches have to be approved by a testing authority, the switch itself needs not be retested. The cores are cast-in at the back of the switch. Their standard length is 500 mm; other lengths are available on request. To connect the cores we recommend the miniterminals from BARTEC.
Technical Data
Protection Class | IP 66 (IEC 60529) |
Dimentions | see data sheet |
Material | plastic (thermoplastics), plunger/additional actuator: stainless steel |
Contact Material | Silver or gold-coated contacts (all contact elements have a standard protective gold-coating as standard) |
Mechanical Life | > 2 x 10^6 switching cycles |
Weight | with 500 mm cores: single-break switch 35 g, double-break switch 70 g |
Voltage | see data sheet |
Current | see data sheet |
Ambient temperature | -60 °C up to +100 °C depending on the type and materials used |
Explosion Protection
Marking | ATEX: Ex II 2G Ex db IIC Gb Ex I M2 Ex db I Mb IECEx: Ex db IIC Gb Ex db I Mb |
Guidelines/Norms | EN 60947-5-1 EN 60947-1 |
Certification | EPS 14 ATEX 1 765 U IECEx EPS 14.0091U NEPSI GYJ11.1606U TC RU C-DE.BH02.B.00222 TÜV 13.1679 U |
- General Info
-
Description
This switching element can be universally used for switching, controlling and regulating operations within Ex-areas. The insert switch is audited by the PTB according to the latest EC guideline 94/9/EC. Devices equipped with these insert switches have to be approved by a testing authority, the switch itself needs not be retested. The cores are cast-in at the back of the switch. Their standard length is 500 mm; other lengths are available on request. To connect the cores we recommend the miniterminals from BARTEC.
- Technical Data
-
Technical Data
Protection Class IP 66 (IEC 60529) Dimentions see data sheet Material plastic (thermoplastics), plunger/additional actuator: stainless steel Contact Material Silver or gold-coated contacts
(all contact elements have a standard protective gold-coating as standard)Mechanical Life > 2 x 10^6 switching cycles Weight with 500 mm cores: single-break switch 35 g, double-break switch 70 g Voltage see data sheet Current see data sheet Ambient temperature -60 °C up to +100 °C
depending on the type and materials used - Explosion Protection
-
Explosion Protection
Marking ATEX:
Ex II 2G Ex db IIC Gb
Ex I M2 Ex db I Mb
IECEx:
Ex db IIC Gb
Ex db I MbGuidelines/Norms EN 60947-5-1
EN 60947-1Certification EPS 14 ATEX 1 765 U
IECEx EPS 14.0091U
NEPSI GYJ11.1606U
TC RU C-DE.BH02.B.00222
TÜV 13.1679 U - Download