Heating tape PSB system

null
Product Description Heating tape PSB system
Product Type 07-5801-….
Brand Bartec
  • Self-regulating
  • Can be cut to length thanks to its parallel current supply
  • Corrosion-proof and resistant to effects of chemicals thanks to its outer sheath
  • Electrically and mechanically protected by a tinned copper braiding
  • Simple installation thanks to its high fl exibility and favourable dimensions

Description

A temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-regulating property prevents overheating even when the tapes are overlapped. Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-regulating heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefi n protects the copper braiding from corrosion and chemical impact. Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket).
The heating system must be designed to ensure that the maximum operating temperature of +65 °C (+150 °F) will not be exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of +85 °C (+185 °F), not more than 1,000 hours cumulated.

Technical Data

Dimensions with braiding and fl uoropolymer jacket:
0.46 in x 0.22 in (11.6 mm x 5.6 mm)
with braiding and polyolefi n jacket:
0.46 in x 0.23 in (11.8 mm x 5.8 mm)
Min. bending radius: 0.98 in (25 mm)
Heat output see data sheet
Voltage AC 120 V, AC 240 V
Resistance Max. braid resistance: < 18.2 Ω/km
Ambient temperature Max. exposure temperature:
switched on +65 °C (+150 °F)
switched off +85 °C (+185 °F)
(cumulative 1000 h)
Min. installation temperature: -55 °C (-67 °F)
Min. start-up temperature: -40 °C (-40 °F)

Explosion Protection

Marking CSA Class I, Div. 2, Groups A, B, C, D
CSA Class II, Div. 2, Groups E, F, G
CSA Class III
Ex II 2G Ex e IIC T5, T6 Gb
Ex II 2D Ex tb IIIC T95 °C, T 80 °C Db
Certification CSA 1862457
KEMA 02ATEX2326 U
IECEx KEMA 07.0047U
Datasheet
General Info

Description

A temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-regulating property prevents overheating even when the tapes are overlapped. Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-regulating heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefi n protects the copper braiding from corrosion and chemical impact. Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket).
The heating system must be designed to ensure that the maximum operating temperature of +65 °C (+150 °F) will not be exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of +85 °C (+185 °F), not more than 1,000 hours cumulated.

Technical Data

Technical Data

Dimensions with braiding and fl uoropolymer jacket:
0.46 in x 0.22 in (11.6 mm x 5.6 mm)
with braiding and polyolefi n jacket:
0.46 in x 0.23 in (11.8 mm x 5.8 mm)
Min. bending radius: 0.98 in (25 mm)
Heat output see data sheet
Voltage AC 120 V, AC 240 V
Resistance Max. braid resistance: < 18.2 Ω/km
Ambient temperature Max. exposure temperature:
switched on +65 °C (+150 °F)
switched off +85 °C (+185 °F)
(cumulative 1000 h)
Min. installation temperature: -55 °C (-67 °F)
Min. start-up temperature: -40 °C (-40 °F)
Explosion Protection

Explosion Protection

Marking CSA Class I, Div. 2, Groups A, B, C, D
CSA Class II, Div. 2, Groups E, F, G
CSA Class III
Ex II 2G Ex e IIC T5, T6 Gb
Ex II 2D Ex tb IIIC T95 °C, T 80 °C Db
Certification CSA 1862457
KEMA 02ATEX2326 U
IECEx KEMA 07.0047U
Download
Datasheet