Self-limiting parallel heating tape PSB
Product Description | Self-limiting parallel heating tape PSB |
Product Type | 07-5801-…. |
Brand | Bartec |
- Self-limiting
- Can be used in explosive atmospheres without temperature limiter
- Can be cut at random length thanks to its parallel current supply
- Corrosion-proof and resistant to effects of chemicals thanks to its outer sheath
- Electrically and mechanically protected by a tinned copper braiding
- Simple installation thanks to its high flexibility and favourable dimensions
Description
A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. A temperature limiter is not necessary (also not in hazardous areas).
Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-limiting heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefin protects the copper braiding from corrosion and chemical impact.
Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket).
Technical Data
Dimensions | with protective braid and protective outer jacket of fluoropolymer: 11.6 x 5.6 mm with protective braid and protective outer jacket of polyolefin: 11.8 x 5.8 mm Min. bending radius: 25 mm |
Heat output | at AC 230 V (+10 °C): 10 W/m, 13 W/m, 15 W/m, 25 W/m, 33 W/m at AC 120 V (+10 °C): 10.6 W/m, 13.7 W/m, 15.8 W/m, 25.8 W/m, 33.6 W/m |
Voltage | AC 208 V up to 254 V AC 110 V up to 120 V |
Resistance | Protective braid: < 18.2 Ω/km |
Ambient temperature | Max. exposure temperature switched on: +65 °C switched off: +85 °C Min. installation temperature: -55 °C Min. start-up temperature: -40 °C |
Explosion Protection
Marking | Ex II 2G Ex e IIC T5, T6 Gb Ex II 2D Ex tb IIIC T95 °C, T 80 °C Db |
Certification | DEKRA 7ATEX0007U IECEx DEK 17.0004U |
- General Info
-
Description
A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. A temperature limiter is not necessary (also not in hazardous areas).
Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-limiting heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefin protects the copper braiding from corrosion and chemical impact.
Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket). - Technical Data
-
Technical Data
Dimensions with protective braid and protective
outer jacket of fluoropolymer: 11.6 x 5.6 mm
with protective braid and protective
outer jacket of polyolefin: 11.8 x 5.8 mm
Min. bending radius: 25 mmHeat output at AC 230 V (+10 °C):
10 W/m, 13 W/m, 15 W/m, 25 W/m, 33 W/m
at AC 120 V (+10 °C):
10.6 W/m, 13.7 W/m, 15.8 W/m, 25.8 W/m, 33.6 W/mVoltage AC 208 V up to 254 V
AC 110 V up to 120 VResistance Protective braid: < 18.2 Ω/km Ambient temperature Max. exposure temperature
switched on: +65 °C
switched off: +85 °C
Min. installation temperature: -55 °C
Min. start-up temperature: -40 °C - Explosion Protection
-
Explosion Protection
Marking Ex II 2G Ex e IIC T5, T6 Gb
Ex II 2D Ex tb IIIC T95 °C, T 80 °C DbCertification DEKRA 7ATEX0007U
IECEx DEK 17.0004U - Download