Self-regulating heating cable HSB+
Product Description | Self-regulating heating cable HSB+ |
Product Type | 07-584B-…F |
Brand | Bartec |
- Can be cut to length at random thanks to its parallel current supply
- Corrosion-proof and resistant to chemical attack thanks to its outer high temperature fluoropolymer protective jacket
- Simple installation thanks favourable dimensions
Description
A temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. Thanks to the parallel design the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. The heating system must be designed to ensure that the maximum exposure temperature of +150 °C will not be exceeded when it is energized
Technical Data
Dimensions | with protective braid and protective outer jacket of fluoropolymer: 11.4 x 5.2 mm Min. bending radius: 40 mm |
Length of heating circuit | see data sheet |
Heat output | at AC 230 V (+10 °C): 15 W/m, 30 W/m, 45 W/m, 60 W/m |
Voltage | AC 208 V up to 277 V 120 V on request |
Ambient temperature | Max. exposure temperature switched on: +150 °C switched off: +225 °C Min. installation temperature: -40 °C Min. start-up temperature: -40 °C |
Explosion Protection
Marking | Ex II 2G Ex e II T3 Gb Ex II 2D Ex tb IIIC T200 °C Db |
Certification | CML 19ATEX3033 IECEx CML 19.0008 |
- General Info
-
Description
A temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. Thanks to the parallel design the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. The heating system must be designed to ensure that the maximum exposure temperature of +150 °C will not be exceeded when it is energized
- Technical Data
-
Technical Data
Dimensions with protective braid and protective outer jacket
of fluoropolymer: 11.4 x 5.2 mm
Min. bending radius: 40 mmLength of heating circuit see data sheet Heat output at AC 230 V (+10 °C):
15 W/m, 30 W/m, 45 W/m, 60 W/mVoltage AC 208 V up to 277 V
120 V on requestAmbient temperature Max. exposure temperature
switched on: +150 °C
switched off: +225 °C
Min. installation temperature: -40 °C
Min. start-up temperature: -40 °C - Explosion Protection
-
Explosion Protection
Marking Ex II 2G Ex e II T3 Gb
Ex II 2D Ex tb IIIC T200 °C DbCertification CML 19ATEX3033
IECEx CML 19.0008 - Download